Skip to content
Get Estimate

Grease Trap and Interceptor Service in Dallas

Grease does not care about your reservation book. Let the trap run past its limit and the first sign is a floor drain backing up into the kitchen, usually mid-service. In Dallas, it is also a compliance item the city inspects.

Every commercial or institutional food service operation in Dallas needs a grease trap, and the city requires it to be fully pumped at least every 90 days, or sooner once grease and solids reach 25% of it. Mainvalve Commercial Plumbing passes your request to an independent local pro who handles pump-outs, line jetting and trap repairs.

Get EstimateCheck your area

Request service

Requests are routed to one local, independent commercial plumber. How this works.

Three-compartment stainless sink and floor drain in a restaurant dish area

Who needs grease trap service in Dallas

If you cook and serve food commercially inside Dallas city limits, this applies to you. Restaurants, cafeterias, bakeries, hotel kitchens, school and hospital kitchens and food halls all fall under it.

Dallas uses "grease trap" for two different devices:

  • Grease trap: usually the smaller indoor unit, under 100 gallons, often steel with one compartment. Many sit under or near a sink.
  • Grease interceptor: usually a large precast concrete tank outside, holding 250 to 5,000 gallons, with two compartments.

Trap size is set by the sizing criteria in the Dallas Plumbing Code. If you are building out or changing your menu volume, size comes first. See restaurant plumbing for the rest of the kitchen.

Signs your grease trap needs service

  • You are near 90 days since the last full pump-out. That is the city's outer limit, not a target.
  • The trap is 25% full. Dallas measures this as floating material, sediment, oils or grease filling 25% or more of the wetted height, from the bottom to the outlet pipe invert.
  • Kitchen drains are slow or a floor sink keeps backing up.
  • There is a grease odor near the trap lid or the dish area.
  • You cannot find your manifests. Dallas expects the final manifest record kept on site for three years.
  • An inspector is coming. The city's liquid waste section inspects grease-generating facilities, restaurants included.

What grease trap service involves

  1. Book a permitted transporter. Pumping must be done by a liquid waste transporter permitted by the City of Dallas and licensed by TCEQ. Ask the pro whether they pump with their own permitted truck or bring in a permitted hauler.
  2. Fill out the manifest first. The transporter must give you a City of Dallas liquid waste manifest (trip ticket) to complete before any waste is removed. Make sure the gallons removed get written down.
  3. Full pump-out, supervised. Dallas requires 100% of the trap's contents removed, and the generator (that is you or your manager) must supervise. Skimming only the top layer does not count.
  4. Line jetting and inspection. While the trap is open, a plumber can jet the kitchen lines feeding it and check baffles, tees and lids. See hydro jetting for how that works.
  5. File the paperwork. Both you and the transporter sign the manifest at pickup. Keep your copy until the final record comes back from the disposal site, then keep that on the premises for three years.

Grit traps are on a separate schedule: Dallas requires cleaning at least once a year, or more often as needed.

Grease trap service cost

These are national ranges from GreaseManagement.org's pricing page, for regularly maintained devices. The real price comes from an on-site look.

ServiceReported range
Indoor grease trap pump and clean$175 to $475
Outdoor grease interceptor pump-out$325 to $950
Neglected trap or interceptorUp to triple the normal price
Hydro jetting a line (Angi)$350 to $600

The cheapest pump-out is the one on schedule. The same pricing page notes that devices allowed to exceed 25% grease and solids cost far more to clean. More numbers are on the commercial plumbing cost page.

What to ask the grease trap pro

  • Is your truck permitted by the City of Dallas, and what is your TCEQ registration number? Both go on the manifest.
  • Do you pump 100% of the contents? Get a yes. Partial pumping leaves solids that harden and cost more next time.
  • Will you record gallons removed on the manifest at pickup?
  • Can you jet the kitchen lines on the same visit, and do you run a camera?
  • What schedule do you recommend for our volume? It should be at least every 90 days.
  • Can you service the grit trap too, if we have one?

The city's grease trap FAQ covers sizing, cleaning frequency and disposal.

Frequently asked

Is a grease trap the same as a grease interceptor in Dallas?

Not physically. A trap is usually a small indoor unit under 100 gallons, and an interceptor is a large outdoor concrete tank of 250 to 5,000 gallons. Dallas uses the term grease trap for both, and the same pumping rules apply.

Can my staff skim the grease trap themselves to stretch the schedule?

Skimming does not meet the Dallas rule. The city requires 100% of the trap's contents removed by a permitted liquid waste transporter, with the full manifest.

How long do I keep grease trap manifests?

Keep your copy until the final record returns from the disposal site. Then keep that final record on the premises for three years, where city staff can review it.

Who is responsible if grease spills during pumping?

Dallas puts that on the generator, the business, to report and clean up spills involving grease, sand or grit and dispose of the material properly. Talk to the transporter about how they prevent spills before they start.

Need a commercial plumber on your schedule?

Send the property, the problem and the best time to reach you. A local commercial plumbing company follows up.

Get Estimate